Due to the high-speed rotation valve switching from one channel to another can be achieved in a minimum of time and with high precision. Nine positions of the valve are connected with reservoirs, one position is used as stop position to stop the flow of perfusion media.
The Perfusion System PS 9 is delivered with a perfusion control software for 64 Bit Windows Systems which is easy to handle and it makes the perfusion process as simple as possible.
The Perfusion System is connected via USB to the Computer. With the perfusion control software a perfusion sequence can be programmed which will be automatically processed after starting. In addition there are program sequences for filling the reservoirs and tubing with buffer solution before starting the experiments and sequences for rinsing the reservoirs and tubing after the experiments.
Reservoirs are special perfusion syringes BD Plastipak with 60 mL volume and can easily be removed for buffer-solution filling or removal. The Perfusion System PS 9 is mounted on a stand and adjustment of height can easily be executed to achieve the desired flow rate. The display in the front shows the currently active channel.

Perfusion System PS9
O-geNOp AV5
ΔC-geNOp AV5
G-geNOp AV5
ΔG-geNOp AV5
C-geNOp AV5
G-geNOp Sensor Cell-line
D1ERCmR2 (ER-targeted physiological KD)
mtD1GO-Cam (mitochondrial physiological KD)
GEPII lc-LysM-GEPII 1.0
mt-GEPII 1.0
NUC lc-LysM-GEPII 1.0
NUC lc-BON-GEPII 1.0
NUC GEPII 1.0
NUC GEPII 2.10
GEPII 2.7 untargeted
mt-lc-BON GEPII 1.0
Bac GEPII 2.7
Bac GEPII 1.0
mt-lc-LysM GEPII 1.0
GEPII lc-BON-GEPII 1.0
Bac lc-LysM GEPII 1.0
NUC GEPII 2.15
GEPII 1.0 untargeted
GEPII 1.0 (cytosolic)
GEPII 2.10 untargeted
CAXX lc-LysM GEPII 1.0
cp450 lc-LysM GEPII 1.0
NUC GEPII 2.7
GEPII 2.15 untargeted
Iron(II) - booster solution
mtG-geNOp (mitochondrial)
geNOps Starter Kit
mtO-geNOp (mitochondrial)
D1GO-Cam (cytosolic physiological KD)
ΔO-geNOp (cytosolic)
ΔC-geNOp (cytosolic)
ΔG-geNOp (cytosolic)
mtΔO-geNOp (mitochondrial)
O-geNOp (cytosolic)
G-geNOp (cytosolic)
mtC-geNOp (mitochondrial)
mtΔC-geNOp (mitochondrial)
pH Lemon cytosolic
pH Lemon GPI
D1CmR2 (cytosolic high KD)
D1ERCR (ER-targeted physiological KD)
mtΔG-geNOp (mitochondrial)
D1ERTG (ER-targeted physiological KD)
mtD1CmR2 (mitochondrial high KD)
ERAT3GR (red-shifted)
ERAT3GR N7Q (red-shifted)
ERAT3GR N7Q R122K R126K (red-shifted; insensitive)
ERAT3GR N7Q YEMK (red-shifted; high affinity)
ERAT3GR R122K R126K (red-shifted; insensitive)
ERAT4.01
ERAT4.01 N7Q
ERAT4.01 N7Q R122K R126K (insensitive)
hEMRE untagged
hEMRE-ECFP
hLETM1 untagged
hMCU -Citrine
hMCU untagged
hMCU-ECFP
Bac GEPII 2.10
Bac GEPII 2.15
Bac lc-Bon GEPII 1.0
D1ERCmR2 AV5
D3GO-Cam (cytosolic low KD)
mtD1GO-Cam AV5
mtD3GO-Cam (mitochondrial low KD)
mtO-GECO1 (mitochondrial physiological KD)
ΔO-geNOp AV5
C-geNOp (cytosolic)
NES GEPII 1.0
NES lc-BON GEPII 1.0
NES lc-LysM GEPII 1.0
hEMRE-Citrine
hEMRE-mCherry
hLETM1-mCherry
hMCU E257Q-mCherry
hMCU-FRET
hMCUb -Citrine
rLetm1-mCherry
rMcu-mCherry
sECFP-hMCU
hMCUb -ECFP
hMCUb -FRET
hMCUb -mCherry
hMCUb untagged
hMCUR1-untagged
hMICU1-Citrine
hMICU1-ECFP
hMICU1-EFhand-mut-Citrine
hMICU1-EFhand-mut-ECFP
hMICU1-FRET
hMICU1-untagged
rMicu1-mCherry
sECFP-hMICU1
hUCP2-Citrine
hUCP2-FLAG
hUCP2-mCherry
hUCP2-R60K-FLAG
hUCP2-R71K-FLAG
hUCP2-untagged
hUCP3-Citrine
hUCP3-ECFP
hUCP3-FRET
hUCP3-R167G
hUCP3-R171G-E172G
hUCP3-untagged
rUcp2-mCherry
pH Lemon LC3B 

Dr. R. Miller –
This is a fantastic device. It works brilliantly. The price is also great; comparable perfusion systems cost >4.000,-$. The software is very intuitive; the Auto Mode is amazingly helpful. I can highly recommend this instrument for performing high-quality live cell imaging experiments.
Ann –
I´m working with this fancy device since appr. 3 weeks and I´m totally convinced and happy with it. This is a great perfusion system. First, I was somewhat concerned that buffers mix up, if I switch over filled and/or empty reservoirs. However, simply closing those tubes, which are not in use, completely avoided any contaminations with unwanted buffers and/or air bubbles. I also very much like the automatic mode, which allows performing experiments precisely in a timesaving manner. In summary, I highly recommend this smart device.